Phoenix™ Modular Facilities
Atec’s Phoenix™ Series Modular Test Facilities are the ideal solution for modern turbine engine testing needs. From APUs to turboprop/turboshaft to low thrust class turbofan engines, Atec has a Phoenix™ Series Modular Test Cell system to meet your needs. Offering all of the functionality of traditional brick and mortar engine test cells with the added benefit of portability, our Phoenix™ Series Modular Test Cells offer our customers a flexible, low-risk, cost-effective engine test cell facility solution.
Our Phoenix™ Series Modular Test Cells have been designed to promote portability. This approach offers our customers greater flexibility while minimizing building structure and site preparation costs. Designed for portability, our Phoenix™ Series systems provide our customer with several distinct advantages over fixed test cell facilities: reduced capital investment, reduced site preparation requirements and cost, reduced on-site start-up time, saving from permitting, remediation and site inspection costs, with the ability to relocate or sell the facility if required. The customer’s investment may be classified as an equipment purchase versus a lease-hold facility improvement for faster depreciation.
FACILITY OVERVIEW

- APU, Turboprop/Turboshaft and Turbofan Versions Available
- Acoustically Treated Enclosure Meeting OSHA Noise Exposure and Local Noise Ordinances
- Skid-Style Substructure to Promote Portability
- Integrated Ballistic Protection for Personnel Safety
- Inlet and Exhaust Passive Acoustic Systems
- Fire Suppression System
- HVAC System
- Fuel Regulation and Measurement System
- Electrical Distribution System
- ADAQ™ Data Acquisition and Control System
- Ancillary Support Systems (as Required)
- Fuel Storage and Delivery System
- Closed-Loop Oil Systems
- Electric/Air/Hydraulic Engine Start Systems
Key Features

- Faster Capital Investment Depreciation (as Equipment) than Traditional Brick and Mortar Test Facilities
- Fully Relocatable
- Minimal Site Preparation and Foundation Requirements
- Reduced Construction Time and Cost
- Fully Contained Facility
- Reduced Installation and Start-Up Time (Pre-Assembled and Tested at Atec’s Facility)
- Proven Approach
APU Phoenix™ Series Modular Test Cells Overview
- 12’ Wide x 12’ Tall x 30’ Long Modular Structure (Approximate Dimensions)
- Resistive/Reactive Load Bank Systems
- Bleed Air Measurement and Loading Systems
- Configurable for Multi-APU Applications
Turboprop/Turboshaft Engine Phoenix™ Series Modular Test Cells Overview

- 12’ Wide x 12’ Tall x 40’ Long Modular Structure (Approximate Dimensions)
- Choice of Engine Loading Systems
- Regenerative Electric Dynamometer – Green Power Approach
- Hydraulic Dynamometer with Complete Closed-Loop Cooling Water System
- Air Dynamometer
- Configurable for Multi-Engine Applications, such as:
- Rolls Royce (Allison) A250 – All Series
- Rolls Royce RR300/RR500
- Pratt Canada PT6 – All Series
- Honeywell TPE331 – All Series
- Honeywell T53
Turbofan and Turbojet Engine Phoenix™ Series Modular Test Cells Overview
- 16’ Wide x 16’ Tall x 60’ Long Modular Structure (Approximate Dimensions)
- Overhead or Floor-Mounted Engine Adapter with Thrust Measurement System
- Configurable for Multi-Engine Applications for Thrust Ratings Up to 15K, such as:
- TFE731
- CF100
- JT15
- JT12
- CJ610
- AE3007
- PW3007
- Avon
- Adour
- J-85